Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
Rattachement africain : fr, ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Purpose: We aimed to evaluate whether virtual non-contrast cerebral computed tomography (VNCCT) reconstructed from intravenous contrast-enhanced dual-energy CT (iv-DECT) could replace non-contrast CT (NCCT) in patients with suspected acute cerebral ischemia. Method: This retrospective study included all consecutive patients in whom NCCT followed by iv-DECT were performed for suspected acute ischemia in our emergency department over a 1-month period. The Alberta Stroke Program Early CT Score (ASPECTS) was used to determine signs of acute ischemia in the anterior and posterior circulation, the presence of hemorrhage, and alternative findings, which were randomly evaluated via the consensus reading of NCCT and VNCCT by two readers blinded to the final diagnosis. An intraclass correlation between VNCCT and NCCT was calculated for the ASPECTS values. Both techniques were evaluated for their ability to detect ischemic lesions (ASPECTS <10) when compared with the final discharge diagnosis (reference standard). Results: Overall, 148 patients (80 men, mean age 64 years) were included, of whom 46 (30%) presented with acute ischemia, 6 (4%) presented with intracerebral hemorrhage, 11 (7%) had an alternative diagnosis, and 85 (59%) had no pathological findings. The intraclass correlation coefficients of the two modalities were 0.97 (0.96–0.98) for the anterior circulation and 0.77 (0.69–0.83) for the posterior circulation. The VNCCT’s sensitivity for detecting acute ischemia was higher (41%, 19/46) than that of NCCT (33%, 15/46). Specificity was similar between the two techniques, at 94% (97/103) and 98% (101/103), respectively. Conclusions: Our results show that VNCCT achieved a similar diagnostic performance as NCCT and could, thus, replace NCCT in assessing patients with suspected acute cerebral ischemia.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
- Date Crossref
- 21/06/2024
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.