Aller au contenu principal
Accès ouvert déclaré 2024 article

The influence of different application patterns of propofol on the sedation courses during drug‐induced sleep endoscopy

1Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Objective: The course of sedation during drug-induced sleep endoscopy (DISE) depends on the application pattern of the sedative drug. The depth of sedation should imitate light and deep sleep as well. Moreover, there should be as many breathing cycles as possible available for observation during light and deep sedation. The aim of the study was to evaluate different rates of propofol application with respect to the achieved depth and length of the course of sedation. Methods: Sixty-three consecutive patients with obstructive sleep apnea and/or snoring undergoing DISE were randomly sedated by propofol perfusion at seven different application patterns: 14, 16, 18, 19, 20, 22 mg/kg/h (0.233, 0.267, 0.3, 0.317, 0.333, 0.367 mg/kg/min) per perfusor and individual bolus application 10 mg each. Sedation depth was monitored by BiSpectral Index™ (BIS). The influence of baseline parameters and the courses of sedation were analyzed. Results: The application rate was the only factor that influenced the depth of sedation. Basic parameters (gender, age, body mass index, apnea-hypopnea index) had no influence on the depth of sedation. The sedation depth was dependent on the rate of propofol application. Regimes at 14 and 16 mg/kg/h as well as bolus application did not reach BIS levels below 50 representing deep sleep. Propofol doses of more than 20 mg/kg/h led to rapid decreases of sedation levels below deep sleep niveau. Propofol rates between 18 and 20 mg/kg/h enable BIS levels below 50 representing deep sleep and providing enough breathing cycles for observation. Conclusion: Lower application rates of propofol provide slower courses of sedation and shallower depths of sedation. A rate of 14 mg/kg/h might be appropriate to reach a sedation plateau at light sleep. A rate of 18 mg/kg/h leads to a sedation, corresponding to deep sleep. The combination of both rates might be a suitable pattern for performing sedation-controlled DISE. Level of evidence: 2: Randomized trial.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The influence of different application patterns of propofol on the sedation courses during drug‐induced sleep endoscopy
Date Crossref
01/06/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Obstructive Sleep Apnea ResearchAnesthesia and Sedative AgentsSleep and Wakefulness Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.