Aller au contenu principal
Accès ouvert déclaré 2024 article

One shot "fire & ice"

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Introduction Pulmonary vein isolation (PVI) is the best and first strategies during ablation of atrial fibrillation (1-4). Short- and long-term effectivity as well as procedure time are important parameters during PVI-ablation. New efforts are made to find longer effectivity, low risk of the procedure and shorter procedure. Purpose The aim of our study is to compare the two "balloon - one shot" methods (radiofrequency balloon "RFB" and cryoballoon "CB") in terms of speed, efficacy and safety. Methods Prospective, randomized, pilot single-center trial including 74 consecutive patients with paroxysmal, persistent or long lasting persistent atrial fibrillation who undergo for the first time PVI-ablation between December 2022 and October 2023. Patient were randomized 1:1 according type of AF, Sex, Hypertension, left ventricular ejection fraction e left atrial volume in a multi-electrode radiofrequency balloon catheter Heliostar ablation or in cryoballoon system ablation. Both groups had comparable clinical characteristics. Results Median Age of the population was 64 year (iq range 57-70), 19 were female (25,7%), 31 patients (42%) had paroxysmal atrial fibrillation, median EF was 60% (iq range 55-65) and median left atrial volume 36 ml/mq (iq 28-40). 37 patients undergo cryoballoon PVI and 37 patients undergo RF balloon Ablation. Compared with the RFB group, the CB group showed a shorter procedure time [65 minutes (55-75) vs. 75 minutes (65-90) (P < 0.008)]. The DAP (dose area product) was lower in RFB Group [7 Gy*cm2 ( 5-10) vs CB Group 11 ( 7-18), p<0,001]. First-pass isolation was comparable. We had 5 complications in RFB group (1 pericardial effusion without pericardiocentesis, 3 transitory ST-elevation on ECG due to air embolism, 1 transient phrenic nerve palsy) and 3 complications in CB group (3 transient phrenic nerve palsy) P=ns. During the procedures in 3 cases of RF group and in 1 case of CB group (p=ns) we had to change the balloon due to technical issues. Conclusion The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. CB has shorter procedural times but with a higher X-Ray exposure.Figure 1Figure 2

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
One shot "fire &amp; ice"
Date Crossref
01/05/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsPericarditis and Cardiac Tamponade

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.