Cost, efficiency, and outcomes of pulsed field ablation vs thermal ablation for atrial fibrillation: A real-world study

77Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: With the exponential growth of catheter ablation for atrial fibrillation (AF), there is increasing interest in associated health care costs. Pulsed field ablation (PFA) using a single-shot pentaspline multielectrode catheter has been shown to be safe and effective for AF ablation, but its cost efficiency compared to conventional thermal ablation modalities (cryoballoon [CB] or radiofrequency [RF]) has not been evaluated. OBJECTIVE: The purpose of this study was to compare cost, efficiency, effectiveness, and safety between PFA, CB, and RF for AF ablation. METHODS: We studied 707 consecutive patients (PFA: 208 [46.0%]; CB: 325 [29.4%]; RF: 174 [24.6%]) undergoing first-time AF ablation. Individual procedural costs were calculated, including equipment, laboratory use, and hospital stay, and compared between ablation modalities, as were effectiveness and safety. RESULTS: Skin-to-skin times and catheter laboratory times were significantly shorter with PFA (68 and 102 minutes, respectively) than with CB (91 and 122 minutes) and RF (89 and 123 minutes) (P < .001). General anesthesia use differed across modalities (PFA 100%; CB 10.2%; RF 61.5%) (P < .001). Major complications occurred in 1% of cases, with no significant differences between modalities. Shorter procedural times resulted in lower staffing and laboratory costs with PFA, but these savings were offset by substantially higher equipment costs, resulting in higher overall median costs with PFA (£10,010) than with CB (£8106) and RF (£8949) (P < .001). CONCLUSION: In this contemporary real-world study of the 3 major AF ablation modalities used concurrently, PFA had shorter skin-to-skin and catheter laboratory times than did CB and RF, with similarly low rates of complications. However, PFA procedures were considerably more expensive, largely because of higher equipment cost.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Cost, efficiency, and outcomes of pulsed field ablation vs thermal ablation for atrial fibrillation: A real-world study
Date Crossref
01/09/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsCoronary Interventions and Diagnostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.