Design and characterisation of a minibeam collimator utilising Monte Carlo simulation and a clinical linear accelerator

5Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Objective. Spatially fractionated radiotherapy is showing promise as a treatment modality. Initial focus was on beams of photons at low energy produced from a synchrotron but more recently research has expanded to include applications in proton therapy. Interest in photon beams remains and this is the focus of this paper Approach. This study presents a 3D printed tungsten minibeam collimator intended to produce peak-to-valley dose ratios (PVDR) of between seven and ten with a 1 MV, bremsstrahlung generated, photon beam. The design of the collimator is motivated by a Monte Carlo study estimating the PVDR for different collimator designs at different energies. This collimator was characterised on a clinical linear accelerator (Elekta VersaHD) as well as an orthovoltage unit. Main results. The performance of the fabricated collimator was measured on Elekta VersaHD running in unflattened mode with a 6 MV beam. On the Elekta VersaHD units the PVDR was measured to be between approximately 1.5 and 2.0 at 3 cm deep. For measurements with the orthovoltage unit PVDRs of greater than 10 were observed at a depth of 4 cm. Significance. The results confirmed that the predictions from simulation could be reproduced on linear accelerators currently in clinical usage, producing PVDRs between 2–2.5. Using the model to predict PVDRs using 1 MV photon beams, the threshold considered to produce enhanced normal tissue dose tolerance ( > 7) was surpassed. This suggests the possibility of using such techniques with versions of existing Linac technology which have been modified to operate at low energy and high beam currents.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Design and characterisation of a minibeam collimator utilising Monte Carlo simulation and a clinical linear accelerator
Date Crossref
19/06/2024
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Therapy and DosimetryAdvanced Radiotherapy TechniquesRadiation Detection and Scintillator Technologies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.