Auto Flow Feature Reduces Dialysate Use While Maintaining Dialysis Adequacy Among In-Center Hemodialysis (HD) Patients
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Adjustment of dialysate flow rate (Qd) as a proportion of blood flow rate (Qb) may lower dialysate consumption. The Auto Flow (AF) feature on Fresenius Medical Care 2008T dialysis machines can make these adjustments automatically. Using real-world data, we investigated the use of the AF feature and its impact on dialysis adequacy among in-center HD patients. Methods: Adult in-center HD patients converting from manual to AF (either 1.5 or 2.0 times the Qb) during 2021 at Renal Research Institute clinics were included. All patients had Kt/V measured 3 months before and after switching to AF and no change in vascular access, dialyzer types or prescribed Qb. Parameters were averaged over each 3-month period before and after switch, and comparisons between time periods were made using paired t-tests. Results: At AF switch, patients (n=48) had mean age of 64 years and vintage of 7 years. Most patients had a fistula (63%) and used Optiflux 180NRe (85%). 46% and 54% patients were switched to AF 1.5 and AF 2.0, respectively. After switch, on average, actual Qd reduced by 37 mL/min; based on the treatment time and actual Qd, we calculated that 8.6 L dialysate volume could be saved per patient per treatment (p<.0001). There was no statistically significant change in mean spKt/V, although there was a numeric increase after switch (table). Sub-analysis by AF 1.5 and 2.0, showed no change in spKt/V among patients switched to AF 1.5 (1.67) and an increase from 1.55 to 1.61 (p=0.06) among those switched to AF 2.0. Conclusions: Use of the Auto Flow feature during HD maintained patients' dialysis adequacy. Based upon actual Qd and treatment time, we can estimate that this would save, on average, 8.6 L of dialysate per patient per treatment (p<0.0001). Funding: Commercial Support - Fresenius Medical Care
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Auto Flow Feature Reduces Dialysate Use While Maintaining Dialysis Adequacy Among In-Center Hemodialysis (HD) Patients
- Date Crossref
- 01/11/2022
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.