Aller au contenu principal
2024 article

One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

PURPOSE: To evaluate the clinical performance of implant-prosthetic rehabilitations carried out using ceramic-coated CAD/CAM titanium abutments. MATERIALS AND METHODS: Thirty implants were placed in 30 patients and rehabilitated with 30 single crowns attached to CAD/CAM titanium abutments. A conventional procedure was applied, implants were placed after postextraction socket healing, and prosthetic restorations were placed after implant healing. Implant lengths ranged from 6 to 15 mm, and widths were 3.6, 4.2, and 4.8 mm. At the time of prosthesis delivery (T0), after 2 years (T1), and after 5 years (T2), the Plaque Index (PI), bleeding on probing (BoP), pocket probing depth (PPD), marginal bone level (MBL), and pink/white esthetic scores (PES/WES) were evaluated for each implant. RESULTS: No patient dropped out of the study during the follow-up period. All 30 implants were clinically successful 5 years after prosthesis delivery (survival rate: 100%) and showed no signs of peri-implant infection. Peri-implant soft tissues were in good health (BoP at T2: 0% in 73% of patients; 25% in 13% of patients; 50% in 10% of patients; and 75% in 3% of patients). The mean PPD was 2.05 ± 0.56 mm at T0, 1.992 ± 0.6 mm at T1, and 1.867 ± 0.439 mm at T2. The mean MBL was 0.413 ± 0.440 mm at T0, 0.306 ± 0.388 mm at T1, and 0.263 ± 0.368 mm at T2. The mean PES, WES, and PES/WES indices (7.43 ± 1.04, 7.57 ± 0.82, and 15.00 ± 1.17, respectively) indicate good integration of soft tissues, satisfactory esthetics, and overall positive outcomes. CONCLUSIONS: The success rates, maintenance of MBLs, and periodontal and esthetic indices suggest the validity of implant-prosthetic rehabilitations with CAD/CAM abutments in cases of single crowns.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study
Date Crossref
01/05/2024
Éditeur
Quintessence Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Dental Implant Techniques and OutcomesDental materials and restorationsOrthopaedic implants and arthroplasty

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.