Aller au contenu principal
2024 article

Analysis after posterior chamber phakic intraocular lens implantation: 17- to 19-year follow-up study

8Citations signalées — pas une note de qualité
3Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

PURPOSE: To evaluate the clinical outcomes of the Visian implantable collamer lens (ICL) in eyes with ≥17 years of follow-up. SETTING: Single-center. DESIGN: Retrospective observational study. METHODS: 70 eyes from 38 patients who underwent surgery between 2002 and 2006 with V4 ICL implantation were analyzed. Preintervention data included corrected distance visual acuity (CDVA), refraction, and intraocular pressure (IOP). At the 19-year mark, CDVA, refraction, IOP, endothelial count, and vault were measured using Tomey Casia 2 anterior pole tomography, along with recording long-term events. RESULTS: The operated patients had a spherical correction between -4 diopters (D) and -21 D and a cylinder up to 7.5 D. The mean CDVA (decimal) at the 17-year check-up was 0.89 ± 0.18, with a spherical equivalent of -1.05 ± 1.36 D. IOP has remained stable because mean measurements before surgery and currently were 15.16 ± 2.54 mm Hg and 16.19 ± 3.29 mm Hg, respectively. The endothelial cell count showed values of 2191 ± 386 cells/mm2, with a maximum of 2804 cells and a minimum of 1125 cells. Finally, the vault obtained was 348.53 ± 234.58 mm. Over the years, 2 eyes developed angle-closure glaucoma and 9 eyes were operated on for the development of anterior subcapsular cataracts. CONCLUSIONS: Visian ICL implantation demonstrated long-term visual and refractive stability, indicating it as a low-risk procedure. The ICL V4 model yielded satisfactory results for myopia and astigmatism correction after 17 years.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analysis after posterior chamber phakic intraocular lens implantation: 17- to 19-year follow-up study
Date Crossref
01/08/2024
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Corneal surgery and disordersIntraocular Surgery and LensesGlaucoma and retinal disorders

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.