Marker‐based C‐arm self‐calibration with unknown calibration pattern

0Citations signalées — pas une note de qualité
11Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Accurate tomographic reconstructions require the knowledge of the actual acquisition geometry. Many mobile C-arm CT scanners have poorly reproducible acquisition geometries and thus need acquisition-specific calibration procedures. Most of geometric self-calibration methods based on projection data either need prior information or are limited to the estimation of a low number of geometric calibration parameters. Other self-calibration methods generally use a calibration pattern with known geometry and are hardly implementable in practice for clinical applications. PURPOSE: We present a three-step marker based self-calibration method which does not require the prior knowledge of the calibration pattern and thus enables the use of calibration patterns with arbitrary markers positions. METHODS: The first step of the method aims at detecting the set of markers of the calibration pattern in each projection of the CT scan and is performed using the YOLO (You Only Look Once) Convolutional Neural Network. The projected marker trajectories are then estimated by a sequential projection-wise marker association scheme based on the Linear Assignment Problem which uses Kalman filters to predict the markers 2D positions in the projections. The acquisition geometry is finally estimated from the marker trajectories using the Bundle-adjustment algorithm. RESULTS: The calibration method has been tested on realistic simulated images of the ICRP (International Commission on Radiological Protection) phantom, using calibration patterns with 10 and 20 markers. The backprojection error was used to evaluate the self-calibration method and exhibited sub-millimeter errors. Real images of two human knees with 10 and 30 markers calibration patterns were then used to perform a qualitative evaluation of the method, which showed a remarkable artifacts reduction and bone structures visibility improvement. CONCLUSIONS: The proposed calibration method gave promising results that pave the way to patient-specific geometric self-calibrations in clinics.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Marker‐based C‐arm self‐calibration with unknown calibration pattern
Date Crossref
30/04/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging Techniques and ApplicationsAdvanced X-ray and CT ImagingDental Radiography and Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.