793 Lightning Burns and General Recommendations
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Introduction The odds of being struck by lightning are one in a million, however lightning strike accounts for 24,000 annual fatalities worldwide (Jensen et al, 2023). Due to its rarity, guidelines for the management of burns acquired by lightning strike are scarce. Current standard of treatment is to treat burns acquired as one would treat electrical burns (Stander & Wallace, 2011). We present a case series of three patients that were struck by lightning and contrast their outcomes to patients with electrical burns. We attempt to provide general recommendations for lightning burns. Methods We conducted retrospective chart review of patients presenting between 2015- 2022 for electrical and lightning burns. SPSS V28 was used for statistical analysis. Lightning burn patients were matched to electric burn patients by age, gender, Total Burn Surface Area (TBSA), and comorbidities. Descriptive statistical analysis was conducted between the three groups due to discrepancies in sample size. Results We report three lightning burn cases: 2 adult males with 1-1.5% TBSA second-degree burns and 1 pediatric case with 4% TBSA. The pediatric case had a more complex hospital course: longer stay (15 vs 4-5 days), ICU stay (13 vs 2 days), and required ventilation but no surgery. In adults aged 19-29, electrical burns patients had longer hospital stays (6.38 vs 5.00 days), similar ICU stays (2.25 vs 2 days), and lower initial CPK (1624.29 vs 3506.00) than lightning burn patients. In those 50+ with TBSA < 5% and hypertension, electrical burns patients had longer stays (6.75 vs 4 days), longer ICU stays (3.25 vs 2.00 days), and lower initial CPK levels (435.5 vs 648.00). CPK normalization took longer for electric burns (29.5 vs 6 hours). In younger patients, lightning burns had lower initial myoglobin (569.30 vs 759.01) but faster normalization (8.5 vs 15.92 hours), while in older patients, myoglobin trends favored lightning burns (6 vs 3.25 hours). Pediatric patients with TBSA < 5% had shorter stays (3.83 vs 15.00 days), ICU stays (0.83 vs 13 days), lower initial CPK (508.25 vs 17393.00), lower myoglobin (91.50 vs 10000.00), and quicker CPK normalization (10.00 vs 14.00) in electric burns compared to lightning burns. Conclusions Electric burns and lightning burns present similarly in adults. Although initial CPK levels are elevated in lightning burn patients, time taken for CPK to trend down was less than electric burn patients. More research is needed on lightning burn management in a pediatric population. Applicability of Research to Practice Lightning burns can be managed similarly to electric burns. Providers ought to expect an increased length of stay in patients who sustain electric burns as well as an extended recovery time for muscular injury.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 793 Lightning Burns and General Recommendations
- Date Crossref
- 17/04/2024
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of South Florida pays non établi dans la noticeUniversité ou école supérieure
-
University of South Florida St. Petersburg pays non établi dans la noticeUniversité ou école supérieure
-
Morsani College of Medicine USF pays non établi dans la noticeUniversité ou école supérieure
University of South Florida, University of South Florida St. Petersburg et Morsani College of Medicine USF.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.