Combining echocardiography and fluoroscopy imaging in real time for left atrial appendage occlusion – single center experience from Poland
Rattachement africain : pl, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Introduction: Atrial fibrillation (AF) presents a growing health concern, often requiring stroke prevention measures, primarily through oral anticoagulation (OAC). Surgical interventions such as left atrial appendage occlusion (LAAO) offer alternatives when OAC is contraindicated. In recent years, percutaneous procedures have gained traction as minimally invasive options, demanding precise anatomical insights. Fusion imaging (FI), which combines transesophageal echocardiography (TEE) and fluoroscopy, has emerged as a potential game-changer in transcatheter interventions. Aim: This study introduces FI to LAAO procedures in Poland, assessing its role in guiding interventions, highlighting advantages, and exploring its potential to reshape cardiovascular interventions. Material and methods: We conducted a retrospective study involving LAAO procedures from March 2015 to December 2018, all utilizing FI. Patient indications, procedural specifics, and safety metrics were collected and analyzed. Follow-ups were conducted at 3 and 6 months. Results: A cohort of 83 patients (mean age: 72.1 ±8.4 years) underwent successful LAAO procedures. FI provided precise device placement and anatomical assessment. Mean procedure time was 54.9 ±34.3 min, contrast medium usage averaged 33.7 ±22.7 ml, and creatinine levels remained stable. Patients were discharged in about 4.2 ±3.4 days. Adverse effects were rare, including minimal bleeding and cardiac tamponade. Follow-ups demonstrated favorable outcomes with low adverse event rates. Conclusions: This study marks the inaugural application of FI in Polish LAAO procedures. FI, offering enhanced visualization and reduced procedure times, holds promise in improving patient safety and treatment efficacy. We recommend its consideration as a standard visualization technique for LAAO procedures.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Combining echocardiography and fluoroscopy imaging in real time for left atrial appendage occlusion – single center experience from Poland
- Date Crossref
- 01/01/2024
- Éditeur
- Termedia Sp. z.o.o.
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.