Aller au contenu principal
Accès ouvert déclaré 2024 preprint

Measuring proximity to standard planes during fetal brain ultrasound scanning

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

This paper presents a pipeline designed to bring ultrasound (US) plane pose estimation closer to clinical use, demonstrating the feasibility of continuous, real-time proximity feedback for navigation to the standard planes (SPs) in the fetal brain. We propose a semi-supervised segmentation model that uses labeled SPs and unlabeled slices from 3D US volumes (non-SPs), achieving 0.93 mean Intersection over Union (mIoU) on SPs and 0.86 mIoU on arbitrary non-SPs. The model incorporates a classification mechanism to identify and filter out frames lacking the fetal brain, and to generate masks for those containing it, enhancing the relevance of plane pose regression in clinical settings. Combined with 6D plane pose regression, our pipeline provides sensorless, continuous proximity detection to SPs with real-time distance metrics rather than binary plane recognition. Furthermore, we validate its translational viability by deploying the system on an NVIDIA Clara AGX edge device, achieving a real-time inference speed of 39 Hz, which exceeds standard clinical acquisition rates. Unlike prior methods validated on curated volume slices, we evaluate the pipeline retrospectively on real fetal scan videos from 17 sonographers of varying expertise: operators freeze near, rather than exactly at, the local minima of the proximity signal, consistent with clinical freeze-timing behavior, whereas proximity alone does not predict expert SP quality scores. The approach complements existing fetal US technologies and is a step toward image-based navigation support in prenatal scanning.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Fetal and Pediatric Neurological DisordersSpeech Recognition and Synthesis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.