Advancing the Diagnosis of Periprosthetic Joint Infections: Integrated Microfluidic Platform for Alpha-Defensins-Specific Aptamer Selection and Its Analytical Applications
Rattachement africain : tw. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Periprosthetic joint infections (PJIs) pose a significant challenge in orthopedic surgery, particularly total joint arthroplasty (TJA), due to the potential for implant failure and increased patient morbidity. Early and accurate detection of PJIs is crucial for timely intervention and better patient prognosis. Herein, we successfully screened a high-affinity aptamer targeting alpha-defensin complex human neutrophil protein 1-3 (HNP 1-3; potential PJI biomarkers in synovial fluid [SF]) for the first time using systematic evolution of ligands by exponential enrichment (SELEX) on an integrated microfluidic platform. The compact microfluidic device enabled efficient screening, with each round completed within <2 h, comprising five rounds of positive selection, two rounds of negative selection, and one round of competitive selection. A novel one-aptamer-one-antibody assay was further developed from the optimal aptamer screened, and it could accurately quantify HNP 1-3 in SF within 3 h with only ∼50 μL of SF. The assay demonstrated strong binding affinity and specificity for the target protein in SF. Thirteen PJI SF samples were accurately diagnosed and the assay was accurate over a wide dynamic range (0.32-100 mg/L). This study has showcased a rapid and accurate diagnostic tool for PJI detection, which should see widespread use in the clinic, holding promise for potential analytical applications in orthopedic surgery and improving patient care.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Advancing the Diagnosis of Periprosthetic Joint Infections: Integrated Microfluidic Platform for Alpha-Defensins-Specific Aptamer Selection and Its Analytical Applications
- Date Crossref
- 09/04/2024
- Éditeur
- American Chemical Society (ACS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.