Aller au contenu principal
Accès ouvert déclaré 2024 article

Transvenous lead advancement in pediatric pacing to overcome growth‐induced lead straightening and stretching

3Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Transvenous lead advancement in pediatric pacing to overcome growth‐induced lead straightening and stretching
Date Crossref
29/03/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesElectronic Packaging and Soldering TechnologiesNeurological disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.