Staphylococcus aureus bacteraemia, cardiac implantable electronic device, extraction, and the risk of recurrent infection; a retrospective population-based cohort study
Rattachement africain : se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: bacteraemia (SAB) are at risk of having CIED infection, pocket infection or endocarditis. To avoid treatment failures, guidelines recommend that the CIED should be extracted in all cases of SAB butrecent studies indicate low extraction rates and low risk of relapse. The aim of the study was to describe a Swedish population-based cohort of patients with CIED and SAB, the rate of extraction, and treatment failure measured as recurrent SAB. METHODS: Patients identified to have SAB in the Karolinska Laboratory database, serving a population of 1.9 million, from January 2015 through December 2019 were matched to the Swedish ICD and Pacemaker Registry. Patients with CIED and SAB were included. Clinical data were collected from medical records. RESULTS: A cohort of 274 patients was identified and 38 patients (14%)had the CIED extracted. Factors associated with extraction were lower age, lower Charlson comorbidity index, shorter time since CIED implantation, and non-nosocomial acquisition, but not mortality. No patient was put on lifelong antibiotic treatment. Sixteen patients (6%) had a recurrent SAB within one year, two in patients subjected to extraction (5%) and 14 in patients not subjected to CIED-extraction (6%). Three of the 14 patients were found to have definite endocarditis during the recurrent episode. CONCLUSIONS: Despite a low extraction rate, there were few recurrences. We suggest that extraction of the CIED might be omitted if pocket infection, changes on the CIED, or definite endocarditis are not detected.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- <i>Staphylococcus aureus</i> bacteraemia, cardiac implantable electronic device, extraction, and the risk of recurrent infection; a retrospective population-based cohort study
- Date Crossref
- 26/03/2024
- Éditeur
- Informa UK Limited
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.