Aller au contenu principal
Accès ouvert déclaré 2024 article

Characteristics Associated With Elevated Time Below Range in Elderly Patients With Type 1 Diabetes Using an Automated Insulin Delivery System

3Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : co. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: This study investigated the characteristics associated with an increased risk of hypoglycemia, in elderly patients with type 1 diabetes mellitus (T1D) using automated insulin delivery (AID) systems. METHODS: Cross-sectional observational study including patients >60 years, using sensor-augmented insulin pump therapy with predictive low-glucose management (SAPT-PLGM), hybrid closed-loop (HCL), and advanced hybrid closed-loop (AHCL), for more than three months. A geriatric assessment was performed, and body composition was determined to investigate its association with achieving time below range (TBR) <70 mg/dL goals. RESULTS: The study included 59 patients (47.5% of men, mean age of 67.6 years, glycated hemoglobin [HbA1c] of 7.5 ± 0.6%, time in range (TIR) 77.8 ± 9.9%). Time below range <70 and <54 mg/dL were 2.2 ± 2.3% and 0.4 ± 0.81%, respectively. Patients with elevated TBR <70 mg/dL (>1%) had higher HbA1c levels, lower TIR, elevated time above range (TAR), and high glycemic variability. Regarding body composition, greater muscle mass, grip strength, and visceral fat were associated with a lower TBR <70 mg/dL. These factors were independent of the type of technology used, but TIR was higher when using AHCL systems compared with SAPT-PLGM and HCL systems. CONCLUSIONS: In elderly patients treated with AID systems with good functional status, lower lean mass, lower grip strength, and lower visceral fat percentage were associated with TBR greater than 1%, regardless of the device used. A similar finding along was found with CGM indicators such as higher HbA1c levels, lower TIR, higher TAR, and higher CV. Geriatric assessment is crucial for personalizing patient management.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Characteristics Associated With Elevated Time Below Range in Elderly Patients With Type 1 Diabetes Using an Automated Insulin Delivery System
Date Crossref
20/03/2024
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Diabetes Management and ResearchHyperglycemia and glycemic control in critically ill and hospitalized patientsDiabetes Treatment and Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.