Preoperative Imaging in Cochlear Implants
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: To determine the utility of computed tomography (CT) and magnetic resonance imaging (MRI) in cochlear implant candidates. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral hospital. PATIENTS: A total of 207 cochlear implanted patients with CT and/or MRI. INTERVENTIONS: N/A. MAIN OUTCOME MEASURES: Age versus abnormal radiologic findings, imaging abnormality versus postoperative outcomes, postoperative outcomes versus electrode design, Cambridge Cochlear Implant Protocol (CCIP) status for imaging abnormalities, sensitivity and specificity of CT and MRI for round-window/cochlear occlusion, and MRI for incomplete partitions. RESULTS: A total of 207 patients with CT, MRI, or both were reviewed retrospectively. Less than half (15.5%) of CT scans had findings that might affect surgical intervention compared with 5.9% of MRI. No significant difference was found between children and adults for relevant imaging abnormalities (grade 4 or higher) with either CT (p = 0.931) or MRI (p = 0.606). CCIP status correlated with cochlear abnormalities (p = 0.040); however, only 46.2% of radiographic abnormalities on CT would be identified by these criteria. For detecting cochlear occlusion requiring surgical intervention, the sensitivity and specificity for CT were 40% (4 of 10; 95% confidence interval [CI], 12.16-73.76) and 95.73% (95% CI, 91.40-98.27), respectively. For MRI, the sensitivity and specificity were 33.33% (1 of 3; 95% CI, 0.84-90.57) and 96.97% (63 of 65; 95% CI, 89.32-99.63), respectively. There was no difference for postoperative AzBio scores for higher-grade imaging abnormalities (p = 0.6012) or for electrode designs (p = 0.3699). CONCLUSIONS: Significant radiographic abnormalities were relatively uncommon in cochlear implant patients on either CT or MRI at our single-center institution. If present, abnormal imaging findings rarely translated to management changes. CCIP status does not reliably predict which patients are likely to have abnormalities. Both MRI and CT have low sensitivity for round-window or cochlear occlusion, but detection likely leads to changes in surgical management.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Preoperative Imaging in Cochlear Implants
- Date Crossref
- 01/04/2024
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.