Utilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Commercially available wearable devices (wearables) show promise for continuous physiological monitoring. Previous works have demonstrated that wearables can be used to detect the onset of acute infectious diseases, particularly those characterized by fever. We aimed to evaluate whether these devices could be used for the more general task of syndromic surveillance. We obtained wearable device data (Oura Ring) from 63,153 participants. We constructed a dataset using participants' wearable device data and participants' responses to daily online questionnaires. We included days from the participants if they (1) completed the questionnaire, (2) reported not experiencing fever and reported a self-collected body temperature below 38 °C (negative class), or reported experiencing fever and reported a self-collected body temperature at or above 38 °C (positive class), and (3) wore the wearable device the nights before and after that day. We used wearable device data (i.e., skin temperature, heart rate, and sleep) from the nights before and after participants' fever day to train a tree-based classifier to detect self-reported fevers. We evaluated the performance of our model using a five-fold cross-validation scheme. Sixteen thousand, seven hundred, and ninety-four participants provided at least one valid ground truth day; there were a total of 724 fever days (positive class examples) from 463 participants and 342,430 non-fever days (negative class examples) from 16,687 participants. Our model exhibited an area under the receiver operating characteristic curve (AUROC) of 0.85 and an average precision (AP) of 0.25. At a sensitivity of 0.50, our calibrated model had a false positive rate of 0.8%. Our results suggest that it might be possible to leverage data from these devices at a public health level for live fever surveillance. Implementing these models could increase our ability to detect disease prevalence and spread in real-time during infectious disease outbreaks.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Utilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach
- Date Crossref
- 12/03/2024
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of California San Diego Shu Chien-Gene Lay Department of Bioengineering pays non établi dans la noticeUniversité ou école supérieure
-
UC San Diego Health System pays non établi dans la noticeÉtablissement de santé
-
University of California UCSF Osher Center for Integrative Health pays non établi dans la noticeUniversité ou école supérieure
-
San Diego Supercomputer Center pays non établi dans la noticeStructure de recherche
-
Baruch College pays non établi dans la noticeUniversité ou école supérieure
-
Zicklin School of Business Department of Management pays non établi dans la noticeUniversité ou école supérieure
Shu Chien-Gene Lay Department of Bioengineering — University of California San Diego, UC San Diego Health System et UCSF Osher Center for Integrative Health — University of California, avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.