Real-world evidence of off-label use of commercially automated insulin delivery systems compared to multiple daily insulin injections in pregnancies complicated by type 1 diabetes

25Citations signalées — pas une note de qualité
21Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Aims:To compare glycemic control and maternal–fetal outcomes of women with type 1 diabetes (T1D) using hybrid closed loop (HCL) versus multiple daily insulin injections (MDI) plus continuous glucose monitoring. Methods:Multicenter prospective cohort study of pregnant women with T1D in Spain. We evaluated HbA1c and time spent within (TIR), below (TBR), and above (TAR) the pregnancy-specific glucose range of 3.5–7.8 mmol/L. Adjusted models were performed for adverse pregnancy outcomes, including baseline maternal characteristics and center. Results:One hundred twelve women were included (HCL n = 59). Women in the HCL group had a longer duration of diabetes and higher rates of prepregnancy care. There was no between-group difference in HbA1c in any trimester. However, in the second trimester, MDI users had a greater decrease in HbA1c (−6.12 ± 9.06 vs. −2.16 ± 7.42 mmol/mol, P = 0.031). No difference in TIR (3.5–7.8 mmol/L) and TAR was observed between HCL and MDI users, but with a higher total insulin dose in the second trimester [+0.13 IU/kg·day)]. HCL therapy was associated with increased maternal weight gain during pregnancy (βadjusted = 3.20 kg, 95% confidence interval [CI] 0.90–5.50). Regarding neonatal outcomes, newborns of HCL users were more likely to have higher birthweight (βadjusted = 279.0 g, 95% CI 39.5–518.5) and macrosomia (ORadjusted = 3.18, 95% CI 1.05–9.67) compared to MDI users. These associations disappeared when maternal weight gain or third trimester HbA1c was included in the models. Conclusions:In a real-world setting, HCL users gained more weight during pregnancy and had larger newborns than MDI users, while achieving similar glycemic control in terms of HbA1c and TIR.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Real-world evidence of off-label use of commercially automated insulin delivery systems compared to multiple daily insulin injections in pregnancies complicated by type 1 diabetes
Date Crossref
28/02/2024
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Diabetes Management and ResearchGestational Diabetes Research and ManagementDiabetes Treatment and Management

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.