Long‐Term Characterization of Indoor Air Quality at a Research Area Building: Comparing Reference Instruments and Low‐Cost Sensors

4Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Indoor particle number size distribution (0.3‐10 μm), equivalent black carbon (eBC), and Ångström absorption exponent (AAE) data were collected in real conditions, over a ten‐month period at a research area building, in a semirural site, to characterize indoor aerosol loading. Additionally, during the campaign, emissions from four indoor sources commonly used at the site (incense, traditional cigarettes, electronic cigarettes, and heat‐not‐burn products) were studied during short‐term experiments with the support of ultrafine particle (UFP) monitoring. Two particle low‐cost sensors (PM LCS), Sensirion SPS30 (0.3‐10 μm), were evaluated in the long‐term campaign and during fast emission processes, to assess their accuracy and reliability. Penetration and infiltration of both fine and coarse particles from outdoor traffic, domestic heating, and dust resuspension were inferred as the main sources of indoor aerosols on a long‐term basis. Moreover, long‐range transported dust aerosols were found to influence indoor coarse number concentration. Among the source events, heat‐not‐burn (HNB) product resulted in the lowest effect on indoor air quality, whereas the highest AAE values from incense and traditional cigarettes suggest the brown carbon (BrC) production. The highest emission of UFP was caused by electronic cigarettes (e‐cig), which spanned particles from the ultrafine to the coarse fractions. This was likely due to the release of metal and silicate from the coil. Analysis of number size distributions of the four experiments revealed the emission of fine particles (0.3‐1 μm) and super micron particles. SPS30s performance was satisfactory in terms of accuracy, precision, and durability, indicating that these devices are suitable for monitoring indoor air quality. Additionally, the two PM LCS were able to detect all simulated fast emission sources.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Long‐Term Characterization of Indoor Air Quality at a Research Area Building: Comparing Reference Instruments and Low‐Cost Sensors
Date Crossref
01/01/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Air Quality Monitoring and ForecastingAir Quality and Health ImpactsVehicle emissions and performance

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.