Aller au contenu principal
Accès ouvert déclaré 2024 article

Using a wearable patch to develop a digital monitoring biomarker of inflammation in response to LPS challenge

9Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : us, be, nl, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Remote inflammation monitoring with digital health technologies (DHTs) would provide valuable information for both clinical research and care. Controlled perturbations of the immune system may reveal physiological signatures which could be used to develop a digital biomarker of inflammatory state. In this study, molecular and physiological profiling was performed following an in vivo lipopolysaccharide (LPS) challenge to develop a digital biomarker of inflammation. Ten healthy volunteers received an intravenous LPS challenge and were monitored for 24 h using the VitalConnect VitalPatch (VitalPatch). VitalPatch measurements included heart rate (HR), heart rate variability (HRV), respiratory rate (RR), and skin temperature (TEMP). Conventional episodic inpatient vital signs and serum proteins were measured pre‐ and post‐LPS challenge. The VitalPatch provided vital signs that were comparable to conventional methods for assessing HR, RR, and TEMP. A pronounced increase was observed in HR, RR, and TEMP as well as a decrease in HRV 1–4 h post‐LPS challenge. The ordering of participants by magnitude of inflammatory cytokine response 2 h post‐LPS challenge was consistent with ordering of participants by change from baseline in vital signs when measured by VitalPatch ( r = 0.73) but not when measured by conventional methods ( r = −0.04). A machine learning model trained on VitalPatch data predicted change from baseline in inflammatory protein response ( R 2 = 0.67). DHTs, such as VitalPatch, can improve upon existing episodic measurements of vital signs by enabling continuous sensing and have the potential for future use as tools to remotely monitor inflammation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Using a wearable patch to develop a digital monitoring biomarker of inflammation in response to <scp>LPS</scp> challenge
Date Crossref
01/02/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlVagus Nerve Stimulation Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.