Aller au contenu principal
Accès ouvert déclaré 2024 preprint

Mighty Tracker -- Performance Studies of the MightyPix for LHCb

1Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

A new downstream tracking system, known as the Mighty Tracker, is planned to be installed at LHCb during LS4 of the LHC. This will allow an increase in instantaneous luminosity from $2\cdot10^{33}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ to $1.5\cdot10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ and therefore an overall higher irradiation and up to six times higher occupancy. To keep the material budget as low or even lower as for the current detector, the Mighty Tracker is planned as a hybrid system with silicon pixels in the inner and scintillating fibers in the outer region. For the pixel detector part HV-CMOS MAPS with a pixel size of $55~\mathrm{x}~165~\mathrm{μm^2}$ will be used. This technology has been chosen because of its low production costs, low material budget, high radiation tolerance and good timing resolution. To fulfill the requirements, the development and characterization of the sensors focuses on radiation damage with fluences up to $2\cdot10^{15~}\mathrm{MeVn_{eq}}/\mathrm{cm^2}$ and a timing resolution $\leq3~\mathrm{ns}$. The timing resolution is restricted due to the $40~\mathrm{MHz}$ trigger-less DAQ by LHCb. To characterize and further develop the MightyPix a new readout system called MARS (Mighty TrAcker Readout System) has been developed. MARS is a modular system, able to test different single chips in the laboratory as well as at testbeam facilities. It has been used to perform first characterization studies of development-chips investigating radiation tolerance and timing resolution as well as the dependence of the sensor settings on the overall performance.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Particle Detector Development and PerformanceMedical Imaging Techniques and ApplicationsParticle physics theoretical and experimental studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.