Aller au contenu principal
Accès ouvert déclaré 2024 article

Hemodynamic study on the therapeutic effects of varying diameter embolic coils in the treatment of intracranial aneurysms

7Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Endovascular coiling is the predominant method for treating cerebral aneurysms. Extensive reports on selecting coil length, hardness, and material are available. However, the impact of coil diameter on postoperative outcomes remains unclear. This study enrolled six personalized geometric models of intracranial aneurysms: three bifurcation aneurysms and three sidewall aneurysms. Four coil models were constructed by changing the coil diameter. Coil embolization was simulated using the finite element method. Computational fluid dynamics was used to characterize hemodynamics in the aneurysms after embolization. Evaluation parameters included velocity reduction, wall shear stress (WSS), low WSS (LWSS), oscillatory shear index (OSI), relative residence time (RRT), and residual flow volume in the aneurysms. At the peak time (t = 0.17 s), the proportion of LWSS area in bifurcation aneurysms increase with the rise in coil diameter: 0.8D, 71.28 ± 12.62% versus 1D, 74.97 ± 19.17% versus 1.2D, 78.88 ± 18.56% versus 1.4D, 84.00 ± 11.53% (mean ± SD). The proportion of high OSI area decreases as the coil diameter increases: 0.8D, 4.41% ± 2.82% versus 1.0D, 3.78 ± 3.33% versus 1.2D, 2.28% ± 1.77% versus 1.4D, 1.58% ± 1.11% (mean ± SD). The proportion of high RRT area increases as the coil diameter rises: 0.8D, 3.40% ± 1.68% versus 1.0D, 7.67 ± 4.12% versus 1.2D, 9.84% ± 9.50% versus 1.4D, 22.29% ± 14.28% (mean ± SD). Side wall aneurysms do not exhibit the aforementioned trend. Bifurcation aneurysms plugged with a coil of 1.4 times the diameter have the largest RFVs (<10 mm/s) within the group. Aforementioned patterns are not found in sidewall aneurysms. In the treatment of aneurysms with coiling, varying coil diameters can result in different hemodynamic environments within the aneurysm. Larger coil diameters have improved hemodynamic performance for bifurcation aneurysms. However, coil diameter and embolization effectiveness have no significant relationship for sidewall aneurysms.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Hemodynamic study on the therapeutic effects of varying diameter embolic coils in the treatment of intracranial aneurysms
Date Crossref
28/01/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Intracranial Aneurysms: Treatment and ComplicationsVascular Malformations Diagnosis and TreatmentAortic Disease and Treatment Approaches

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.