Prospective single-center study on the reliability of ipsilateral cerebral oximetry using near-infrared spectroscopy as a predictor for selective shunting during carotid endarterectomy
Rattachement africain : sa. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: Many techniques are available for the intraoperative assessment of brain perfusion during carotid endarterectomy, such as carotid stump pressure, near-infrared spectroscopy, somatosensory evoked potentials, transcranial Doppler, electroencephalography, and clinical assessment. The decision for selective carotid shunt insertion is dependent on clinical deterioration or the detection of cerebral hypoperfusion after cross-clamping of the internal carotid artery. Monitoring cerebral oximetry using near-infrared spectroscopy is a noninvasive technique for cerebral oxygen saturation measurement, reflecting changes in cerebral blood flow during carotid endarterectomy. The aim of this study was to evaluate the reliability of near-infrared spectroscopy as a predictor of selective shunting during carotid endarterectomy. METHODS: In total, 47 conventional carotid endarterectomy surgeries were performed at our hospital between March 2016 and December 2021. All surgeries were performed under a regional cervical block supplemented with local infiltration anesthesia. All patients were monitored by cerebral oximetry using bilateral near-infrared spectroscopy probes and clinical assessment through communication with the patient (numerical, visual, and verbal) to indicate a selective shunt. Near-infrared spectroscopy values were recorded before and after internal carotid cross-clamping and after declamping. Any decrease in ipsilateral cerebral oximetry-near-infrared spectroscopy values equal to or more than 20% from the pre-clamping baseline reading associated with deterioration in neurological status (hemiparesis, aphasia, or deterioration in level of consciousness) after internal carotid artery cross-clamping was considered an indication for intraluminal carotid shunting. RESULTS: After internal carotid artery cross-clamping, 5 of 47 patients (10.6%) developed a significant drop in cerebral oxygen saturation associated with obvious clinical assessment deterioration in verbal communication and weakness in contralateral arm power. A Pruitt-Inahara carotid shunt was subsequently inserted, and 42 patients remained stable throughout surgery. The average decline in ipsilateral near-infrared spectroscopy values was 23.8% in patients with clinical deterioration. The average decline was 8.6% in patients who remained stable. CONCLUSIONS: Monitoring ipsilateral cerebral oximetry using near-infrared spectroscopy is an easy and reliable method for indicating selective shunting during carotid endarterectomy. A 20% decrease in ipsilateral brain tissue oximetry after internal carotid artery cross-clamping provides a reliable cut-off value for selective intraluminal carotid shunting during carotid endarterectomy.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Prospective single-center study on the reliability of ipsilateral cerebral oximetry using near-infrared spectroscopy as a predictor for selective shunting during carotid endarterectomy
- Date Crossref
- 28/01/2024
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.