Aller au contenu principal
Accès ouvert déclaré 2024 article

A new designed full process coverage robot-assisted total hip arthroplasty: a multicentre randomized clinical trial

18Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVE: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. METHODS: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA ( n =74 patients) and MTHA ( n =74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. RESULTS: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate ( P >0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71±25.22 min vs. 79.42±16.16 min; t=7.30, P <0.05). The femoral angulation (1.78°±0.64°) and LLD (2.87±1.55 mm) in the RA-THA group were significantly lesser than those in the MTHA group (2.22°±1.11° and 5.81±6.27 mm, respectively; t=-2.95 and t=-3.88, P <0.05). CONCLUSION: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A new designed full process coverage robot-assisted total hip arthroplasty: a multicentre randomized clinical trial
Date Crossref
19/01/2024
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Orthopaedic implants and arthroplastyTotal Knee Arthroplasty OutcomesManagement of metastatic bone disease