Aller au contenu principal
Accès ouvert déclaré 2023 preprint

Time Projection Chamber for GADGET II

0Citations signalées, ce qui n’est pas une note de qualité
9Institutions déclarées
6Pays d’affiliation déclarés

Rattachement africain : us, fr, es, il, ca, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: The established GADGET detection system, designed for measuring weak, low-energy $β$-delayed proton decays, features a gaseous Proton Detector with MICROMEGAS readout for calorimetric particle detection, surrounded by a Segmented Germanium Array for high-resolution prompt $γ$-ray detection. Purpose: To upgrade GADGET's Proton Detector to operate as a compact Time Projection Chamber (TPC) for the detection, 3D imaging and identification of low-energy $β$-delayed single- and multi-particle emissions mainly of interest to astrophysical studies. Method: A new high granularity MM board with 1024 pads has been designed, fabricated, installed and tested. A high-density data acquisition system based on Generic Electronics for TPCs has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a $^{220}$Rn $α$-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the ATTPCROOT data analysis framework. Further, a novel application of 2D convolutional neural networks for GADGET II event classification is introduced. Results: The GADGET II TPC is capable of detecting and identifying $α$-particles, as well as measuring their track direction, range, and energy. It has also been demonstrated that the GADGET II TPC is capable of tracking cosmic-ray muons. In addition to being one of the first generation of micro pattern gaseous detectors to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium $γ$-ray detectors. \textbf{Conclusions:} The TPC of GADGET II has been designed, fabricated, tested, and is ready for operation at the FRIB for radioactive beam-line experiments.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Particle Detector Development and PerformanceDark Matter and Cosmic PhenomenaNeutrino Physics Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.