Short-term results of tibial interference screw fixation for transtibial medial meniscus posterior root pull-out repair
Rattachement africain : at, de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: To evaluate the technique of transtibial pull-out repair with tibial interference screw fixation for medial meniscus posterior root (MMPR) tear by reporting on short-term outcomes and complications. Methods: All MMPR repairs performed between January 2019 and August 2021 (n = 70) were retrospectively screened regarding demographic data and surgical parameters. The patients were questioned for performed revision surgery, symptoms and complications. The Numeric Rating Scale (NRS) for pain, Lysholm Knee Score and International Knee Documentation Committee Subjective Knee Form (IKDC) questionnaires were used to evaluate clinical outcome. In cases of revision surgery for re-tear the mode of failure was intraoperatively classified (patients with re-tear were excluded from the clinical follow-up examination). The influence of demographic and treatment parameters (surgical and rehabilitation) on the incidence and mode of re-tear and clinical scores was evaluated. Results: After 2.3 ± 0.7 years, 62 patients (88.6 %) were available for follow-up. There were no direct intra- or postoperative complications. No revision was performed due to symptoms related to the tibial fixation material. The mean surgery time was 33.5 ± 10.8 min. The overall re-tear rate was 17.7 % (11 patients) of whom 10 were treated surgically and one conservatively. Primary mode of failure was suture cut-out from the meniscus (70 %). The NRS, Lysholm Knee Score and subjective IKDC were obtained in 38 patients and improved from 6.8 ± 2.4, 40.1 ± 23.9 and 32.8 ± 16.3 to 2.2 ± 2.2, 80.5 ± 16.3 and 63.0 ± 13.9, respectively (all p < 0.001). No influence was observed from demographic and treatment parameters on re-tear rates or clinical Scores. Conclusions: Tibial interference screw fixation is a fast and promising technique for MMPR transtibial pull-out repair. In the presented technique, utilizing non-absorbable locking sutures alongside tibial interfenrence screw fixation, the primary mode of failure was suture cut-out from the meniscus.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Short-term results of tibial interference screw fixation for transtibial medial meniscus posterior root pull-out repair
- Date Crossref
- 01/04/2024
- Éditeur
- Scientific Scholar
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Innsbruck Medical University pays non établi dans la noticeUniversité ou école supérieure
-
Universität Innsbruck pays non établi dans la noticeUniversité ou école supérieure
-
Paracelsus Medizinische Privatuniversität pays non établi dans la noticeUniversité ou école supérieure
-
Orthopedic Hospital Markgroeningen Centre for Sports Orthopedics and Special Joint Surgery pays non établi dans la noticeÉtablissement de santé
-
Medical University of Innsbruck Department of Orthopaedics and Traumatology pays non établi dans la noticeUniversité ou école supérieure
-
Paracelsus Medical Private University pays non établi dans la noticeUniversité ou école supérieure
Innsbruck Medical University, Universität Innsbruck et Paracelsus Medizinische Privatuniversität, avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.