A 3D-printed fence-surface plasma source for skin treatment and its potential for personalized medical application
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract A 3D-printed fence-surface electrode that has the potential for personalized medical application is fabricated in this study. The framework of the 3D-printed fence electrode could be any shape to fit the outline of the target. Here, the fence electrode with an area of 50 × 50 mm is made as an example to study the discharge characteristic and the affecting factors (number of bars and the curvature of the electrode). The results show that more bars of the fence electrode with the same area will have a larger discharge current and a more uniform glowing area, which is consistent with the numerical results. When introducing the human load, it will not affect the original discharge between the fence and the ground electrodes but will add discharging channels between the fence electrode and the human load when the load contacts the fence electrode. In the worst case, the maximum root-mean-square of the discharge current flowing through the human model is 5.9 mA, which is still lower than the safety thresholds. The highest temperature rise on the surface of the fence electrode is 35.226.55 °C at the condition of 15 bars for 7 kV, 3 min running. It needs a 60 s treatment for Escherichia coli and Staphylococcus aureus to get a sterilization rate of 99.99% while it needs about 180 s treatment for Pseudomonas aeruginosa to get the same rate. Finally, the procedure for designing a personalized fence-surface plasma source is illustrated and the electrodes used to fit the calf and heel are made. The discharge of the personalized fence-electrode is stable and could be used in personalized plasma medicine in the future.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A 3D-printed fence-surface plasma source for skin treatment and its potential for personalized medical application
- Date Crossref
- 28/12/2023
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Nanjing Tech University pays non établi dans la noticeUniversité ou école supérieure
-
School of Electrical Engineering and Control Science pays non établi dans la noticeUniversité ou école supérieure
Nanjing Tech University et School of Electrical Engineering and Control Science.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.