Woven EndoBridge Device for Unruptured Wide-Neck Bifurcation Aneurysm: A Multicenter 5-Year Follow-up
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND AND OBJECTIVES: This multicenter study aimed to assess the safety and efficacy of the Woven EndoBridge (WEB) device for treating unruptured wide-neck intracranial bifurcation aneurysms (WIBAs) with short-, mid-, and long-term follow-ups (FUPs). METHODS: Consecutive patients with unruptured WIBAs treated with WEB between December 2014 and January 2018 were included. Patient, aneurysm, and device characteristics were collected and analyzed retrospectively. Morbidity and mortality rates were determined by collecting intraprocedural, periprocedural, and delayed complications. Aneurysm occlusion was assessed at 1, 3, and 5 years using a 3-grade scale: complete occlusion, neck remnant, and residual aneurysm. Complete occlusion and neck remnant were considered as adequate occlusion. Patients who received re-treatment were also evaluated. RESULTS: The study included 104 consecutive patients (55.8% female, mean age 58.6 ± 11.8 years). Aneurysm maximum size, neck, and dome-to-neck mean were, respectively, 6.9 ± 2.1 mm, 4.5 ± 1.2 mm, and 1.4 ± 0.3 mm. One-year FUP was collected for 95 patients, and 3- and 5-year FUPs were collected for 83 patients. Adequate occlusion was observed at 1-year FUP in 90.5% (86/95), 91.6% (76/83) was observed at 3-year FUP, and 92.8% (77/83) at 5-year FUP. None of the aneurysms bled after treatment. During FUP, 6/83 patients (7.2%) were re-treated for residual aneurysm. Morbidity and mortality rates closely related to aneurysm occlusion were 0% (0/104). CONCLUSION: The WEB device was safe and effective for treating unruptured WIBAs, both in short-term and long-term FUPs.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Woven EndoBridge Device for Unruptured Wide-Neck Bifurcation Aneurysm: A Multicenter 5-Year Follow-up
- Date Crossref
- 01/12/2023
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.