Analysis of false-positive and false-negative results in 99mTc-MIBI SPECT/CT parathyroid imaging

10Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : cn, gb, th. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason. Methods: The data from 314 patients with suspected HPT who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2011 and 2022 were retrospectively evaluated. The sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of parathyroid 99mTc-MIBI SPECT/CT were calculated, and the false-positive (FP) and FN findings were analyzed. Results: Accurate localization by 99mTc-MIBI SPECT/CT was significantly associated with the parathyroid hormone (PTH) level. The 99mTc-MIBI SPECT/CT for diagnosis/lesion location reached a sensitivity of 84.6%/56.8%, a PPV of 97.3%/98.4%, an NPV of only 23.7%/4.18%, and an accuracy of 83.4%/57.1%, respectively. The largest diameter, shortest diameter, and lesion volume were lower in the FN group than in the TP group. A total of 7 FP cases were found, including 2 cases of thyroid nodules, 4 cases of thyroid tissue, and 1 case of hibernoma. A total of 45 FN patients, including 321 FN lesions, were confirmed, of which parathyroid hyperplasia accounted for 97.8%. Lesion weights greater than 20 µg were able to be detected, but lightweight lesions less than 100 mg were the principal source of FN results, accounting for approximately 39.3%. With lesion weights 0–100, 101–300, 301–1,000, and >1,000 mg, the FN rate was 70.8% (126/178), 51.8% (103/199), 34.6% (81/234), and 8.33% (11/132), respectively. Conclusions: 99mTc-MIBI SPECT/CT parathyroid imaging provides good sensitivity and high specificity in HPT location. Correct localization by 99mTc-MIBI SPECT/CT correlates positively with lesion weight and PTH levels. The smaller the lesion, the higher the FN rate in 99mTc-MIBI SPECT/CT parathyroid imaging, and lesions weighing less than 100 mg are the main source of FN results in 99mTc-MIBI SPECT/CT parathyroid imaging.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analysis of false-positive and false-negative results in 99mTc-MIBI SPECT/CT parathyroid imaging
Date Crossref
01/12/2023
Éditeur
AME Publishing Company
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Parathyroid Disorders and TreatmentsThyroid and Parathyroid SurgeryMedical Imaging and Pathology Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.