Accuracy of Toric Intraocular Lens Calculations Using Estimated Versus Measured Posterior Corneal Astigmatism

6Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : us, nl, il, au. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To compare the prediction accuracy of toric intraocular lens calculations using estimated vs measured posterior corneal astigmatism (PCA). DESIGN: Retrospective case series. METHODS: A total of 110 eyes of 110 patients with uncomplicated toric intraocular lens implantation were included in this study. Predicted postoperative refractive astigmatism was calculated with the Barrett Toric Calculator using the estimated PCA (E-PCA), the measured IOLMaster 700 PCA (I-PCA), and the measured Pentacam PCA (P-PCA). Refractive astigmatism prediction errors (RA-PEs), including their trimmed (tr-) centroid (mean vector), spread (precision), tr-mean absolute RA-PE (accuracy), and percentage within a certain threshold, were determined using vector analysis and compared between groups. SETTING: University Eye Clinic, Maastricht University Medical Center+, the Netherlands. RESULTS: The tr-centroid RA-PEs of the E-PCA (0.02 diopter [D] at 82.2°), the I-PCA (0.08 D at 35.5°), and the P-PCA (0.09 D at 69.1°) were significantly different from each other (P < .01), but not significantly different from zero (P = .75, P = .05, and P = .05, respectively). The E-PCA had the best precision (tr-mean 0.40 D), which was not significantly lower than the I-PCA (0.42 D, P = .53) and P-PCA (0.43 D, P = .06). The E-PCA also had the best accuracy (0.40 D), which was not significantly different from the I-PCA (0.42 D, P = .26) and significantly better than the P-PCA (0.44 D, P < .01). The precision and accuracy of the I-PCA did not significantly differ from those of the P-PCA. There were no statistically significant differences in the percentage of eyes within a certain absolute RA-PE threshold. CONCLUSIONS: The Barrett Toric Calculator using the E-PCA, I-PCA, or P-PCA showed a comparable prediction of postoperative refractive astigmatism in standard clinical practice.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Accuracy of Toric Intraocular Lens Calculations Using Estimated Versus Measured Posterior Corneal Astigmatism
Date Crossref
01/06/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ophthalmology and Visual Impairment StudiesCorneal surgery and disordersGlaucoma and retinal disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.