Preclinical safety evaluation of continuous UV-A lighting in an operative setting

3Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Germicidal ultraviolet (UV-C) light has been shown as an effective modality for disinfection in laboratory settings and in the operative room. Traditionally, short-wavelength UV-C devices, which have previously been shown to cause DNA damage, are utilized only for disinfection in pre- and post-operative settings and are not continuously active during operations. Continuous use of intraoperative UV light has potential to decrease pathogens and subsequent surgical site infections (SSIs), which arise in approximately 5-15% of operative cases. SSIs are a significant determinant of patient morbidity, readmission rates, and overall cost. Therefore, a method of UV light disinfection with a low risk of DNA damage is needed so that greater antimicrobial protection can be afforded to patients during the entirety of their surgical procedures. A new disinfection device that harnesses longer-wavelength UV-A light to disinfect the surgical field throughout the entirety of the procedure, including pre- and post-operation has been developed. METHODS: This study aimed to determine if UV-A light administered intraoperatively was safe, as defined by the minimal presence of DNA damage and safe amounts of reflection upon medical personnel. Using in vitro models, we examined the differential impacts of UV-C and UV-A light on DNA damage and repair pathways. In a murine model, we looked at the production of DNA damage photoproduction in relation to UV-A versus UV-C exposure. RESULTS: Our results show UV-A light does not induce a significant amount of DNA damage at the cellular or tissue level. Furthermore, a preclinical porcine study showed that surgical personnel were exposed to safe levels of UV-A irradiance from an overhead UV-A light used during an operation. The amount of UV-A transmitted through surgical personal protective equipment (PPE) also remained within safe levels. CONCLUSIONS: In conclusion, we found that UV-A may be safe for intraoperative use.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Preclinical safety evaluation of continuous UV-A lighting in an operative setting
Date Crossref
17/11/2023
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Alabama at Birmingham Department of Surgery pays non établi dans la notice
    Université ou école supérieure
  • a Daintree Company GE Current pays non établi dans la notice
    Entreprise

Department of Surgery — University of Alabama at Birmingham et GE Current — a Daintree Company.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Device Sterilization and DisinfectionInfection Control in HealthcareSkin Protection and Aging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.