Endoscopist‐related factors affecting adenoma detection during colonoscopy: Data from the J‐SCOUT study
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVES: Colonoscopy withdrawal times are associated with the adenoma detection rate (ADR). However, the relationship between ADR and cecal insertion time has been inadequately characterized. We aimed to evaluate endoscopist-related factors involved in the ADR, including the average individual colonoscopy insertion and withdrawal times. METHODS: This observational study used a colonoscopy database with pathology data from routine clinical practice in Japanese institutions. The odds ratios (OR) of endoscopist-related factors related to ADRs were examined using a generalized linear mixed model. RESULTS: Of the 186,293 colonoscopies performed during the study period, 47,705 colonoscopies by 189 endoscopists in four hospitals were analyzed for ADR. The overall ADR was 38.3% (95% confidence interval [CI] 37.8, 38.7). Compared to endoscopists with mean cecal insertion times of <5 min, the OR of ADR for those with mean cecal insertion times of 5-9, 10-14, and ≥15 min were 0.84 (95% CI 0.71, 0.99), 0.68 (95% CI 0.52, 0.90), and 0.45 (95% CI 0.25, 0.78), respectively. Compared to endoscopists with mean withdrawal times of <6 min, the OR of ADR for those with mean withdrawal times of 6-9, 10-14, and ≥15 min were 1.38 (95% CI 1.03, 1.85), 1.48 (95% CI 1.09, 2.02), and 1.68 (95% CI 1.04, 2.61), respectively. There were no significant differences in ADRs by endoscopist specialty, gender, or the total number of examinations performed. CONCLUSION: Individual mean colonoscopy insertion time was associated with ADR and might be considered as a colonoscopy quality indicator as well as withdrawal time.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Endoscopist‐related factors affecting adenoma detection during colonoscopy: Data from the J‐SCOUT study
- Date Crossref
- 11/12/2023
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.