4DCT in Discordant Parathyroid Adenoma Scans: Case Series and Meta‐Analysis
Rattachement africain : il. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: To evaluate the accuracy of four-dimensional computerized-tomography (4DCT) for localizing parathyroid adenomas (PTAs) in cases with discordant or non-localizing ultrasonography (US) and Technetium-99 sestamibi (MIBI) scans. DATA SOURCES: Retrospective case series and systematic review. REVIEW METHODS: A case series and meta-analysis of patients diagnosed with primary hyperparathyroidism and discordant US and MIBI scans who underwent 4DCT prior to surgery. A comprehensive search for all relevant publications in the English literature between December 2006 and March 2022 was conducted for the meta-analysis. Patients undergoing parathyroidectomy between January 2015 and December 2021 were identified from the institutional electronic database for the case series. All studies were analyzed for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the 4DCT adenoma localization capabilities. RESULTS: Thirteen retrospective studies that included 379 patients and one case series that included 37 patients were identified and analyzed. A per-patient analysis revealed sensitivity for lateralization to the correct side (n = 181) ranging from 80% to 100% with a fixed effects model of 89% (95%confidence interval [CI]: 82%-93%) and a PPV for lateralization ranging from 63%-95% with a random effects model of 87% (95% CI: 77%-95%). Sensitivity of localization to the correct quadrant (n = 172) ranged from 53% to 100% with a random effects model of 90.4% (95% CI: 76%-99%), and the PPV for localization ranged from 52% to 100% with a random effects model of 82% (95% CI: 73%-89%). CONCLUSION: 4DCT enhances imaging capabilities of localizing PTAs in cases of discordant or non-localizing US and MIBI scans. LEVEL OF EVIDENCE: NA Laryngoscope, 134:2198-2205, 2024.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- <scp>4DCT</scp> in Discordant Parathyroid Adenoma Scans: Case Series and <scp>Meta‐Analysis</scp>
- Date Crossref
- 06/11/2023
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.