Flexible in-cavity MRI receiving coil for ultra–high-resolution imaging of the pituitary gland
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: The objective of this study was the preclinical design and construction of a flexible intrasphenoid coil aiming for submillimeter resolution of the human pituitary gland. METHODS: Sphenoid sinus measurements determined coil design constraints for use in > 95% of adult patients. Temperature safety parameters were tested. The 2-cm-diameter coil prototype was positioned in the sphenoid sinus of cadaveric human heads utilizing the transnasal endoscopic approach that is used clinically. Signal-to-noise ratio (SNR) was estimated for the transnasal coil prototype compared with a standard clinical head coil. One cadaveric pituitary gland was explanted and histologically examined for correlation to the imaging findings. RESULTS: With the coil positioned directly atop the sella turcica at a 0° angle of the B0 static field, the craniocaudal distance (21.2 ± 0.8 mm) was the limiting constraint. Phantom experiments showed no detectable change in temperature at two sites over 15 minutes. The flexible coil was placed transnasally in cadaveric specimens using an endoscopic approach. The image quality was subjectively superior at higher spatial resolutions relative to that with the commercial 20-channel head coil. An average 17-fold increase in the SNR was achieved within the pituitary gland. Subtle findings visualized only with the transnasal coil had potential pathological correlation with immunohistochemical findings. CONCLUSIONS: A transnasal radiofrequency coil feasibly provides a 17-fold boost in the SNR at 3 T. The ability to safely improve the quality of pituitary imaging may be helpful in the identification and subsequent resection of small functional pituitary lesions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Flexible in-cavity MRI receiving coil for ultra–high-resolution imaging of the pituitary gland
- Date Crossref
- 01/05/2024
- Éditeur
- Journal of Neurosurgery Publishing Group (JNSPG)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.