Aller au contenu principal
Accès ouvert déclaré 2023 article

Reliability, accuracy, and minimal detectable difference of a mixed concept marker set for finger kinematic evaluation

2Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

The study of finger biomechanics requires special tools for accurately recording finger joint data. A marker set to evaluate finger postures during activities of daily living is needed to understand finger biomechanics in order to improve prosthesis design and clinical interventions. The purpose of this study was to evaluate the reliability of a proposed hand marker set (the Warwick marker set) to capture finger kinematics using motion capture. The marker set consisted of the application of two and three marker clusters to the fingers of twelve participants who participated in the tests across two sessions. Calibration markers were applied using a custom palpation technique. Each participant performed a series of range of motion movements and held a set of objects. Intra and inter-session reliability was calculated as well as Standard Error of Measurement (SEM) and Minimal Detectable Difference (MDD). The findings showed varying levels of intra- and inter-session reliability, ranging from poor to excellent. The SEM and MDD values were lower for the intra-session range of motion and grasp evaluation. The reduced reliability can potentially be attributed to skin artifacts, differences in marker placement, and the inherent kinematic variability of finger motion. The proposed marker set shows potential to assess finger postures and analyse activities of daily living, primarily within the context of single session tests.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Reliability, accuracy, and minimal detectable difference of a mixed concept marker set for finger kinematic evaluation
Date Crossref
01/11/2023
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Muscle activation and electromyography studiesStroke Rehabilitation and RecoveryOrthopedic Surgery and Rehabilitation

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.