Comparing outcomes of thulium fiber laser versus high-power Holmium:YAG laser lithotripsy in pediatric patients managed with RIRS for kidney stones. A multicenter retrospective study
Rattachement africain : it, fr, hk, tr, sg, gb, in. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: The aim of this study was to evaluate thulium fiber laser (TFL) safety and efficacy compared to high-power (HP) Holmium:YAG laser in pediatric patients who have undergone retrograde intrarenal surgery (RIRS) for kidney stones.METHODS: We retrospectively reviewed data from pediatric patients who underwent RIRS for kidney stones between 2018 and 2020. Complications were assessed 4-6 weeks postoperatively. Stone-free (SF) was defined as the absence of visible fragments or as the presence of a single residual fragment ≤2 mm at 3 months postoperative imaging. Student’s t-test for continuous variables, and χ2 and Fisher’s Exact Test for categorical variables were used to compare outcomes between patients treated with HP Holmium:YAG (group 1) and TFL (group 2). Univariate (UVA) and multivariate (MVA) logistic regression analyses were performed to predict SF-associated factors.RESULTS: Data from 126 pediatric patients were analyzed, 97 in group 1 and 29 in group 2. Preoperative characteristics were similar between cohorts. No major complication occurred in both groups. Group 2 had a shorter operative time (mean time 49.5 vs. 64.3 min, P=0.024). SF rate was 81.4% and 89.7% (P=0.45) and reintervention rate was 14.4% and 6.89% (P=0.046) in group 1 and 2, respectively. At UVA and MVA, the type of laser did not influence SF rate. However, prestenting and single stones were positively associated with SR rate.CONCLUSIONS: Both laser technologies are safe and effective and showed similar SF rates. TFL showed less operative time and lower re-intervention rate compared to HP Holmium:YAG. Further prospective studies are needed to corroborate our findings.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparing outcomes of thulium fiber laser versus high-power Holmium:YAG laser lithotripsy in pediatric patients managed with RIRS for kidney stones. A multicenter retrospective study
- Date Crossref
- 01/10/2023
- Éditeur
- Edizioni Minerva Medica
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées