Aller au contenu principal
Accès ouvert déclaré 2023 article

A comparative study between surgical cut down and percutaneous closure devices in management of large bore arterial access

7Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : Égypte. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Compared to conventional open surgery, minimally invasive catheter-based procedures have less post procedural complications. Transcatheter aortic valve implantation (TAVI) and endovascular aneurysm repair (EVAR) require large bore arterial access. Optimal site management of large bore arterial access is pivotal to reduce the hospital-acquired complications associated with large bore arterial access. We wanted to compare surgical cutdown versus percutaneous closure devices in site management of large bore arterial access. METHODS: Participants planned for TAVI or EVAR with large bore arterial access more than 10 French were included, while participants with history of bypass surgery, malignancies, thrombophilia, or sepsis were excluded. A consecutive sample of 100 participants (mean age 74.66 ± 2.65 years, 61% males) was selected, underwent TAVI or EVAR with surgical cutdown (group 1) versus TAVI or EVAR with Proglide™ percutaneous closure device (group 2). RESULTS: The incidence rate of hematoma was significantly lower in group 2 versus group 1 (p = 0.014), the mean procedure time (minutes) and the median hospital stay (days) were significantly higher in group 1 versus group 2 (t(98) = - 2.631, p = 0.01, and U = 2.403, p = 0.018, respectively), and the c-reactive protein pre-procedure and the c-reactive protein post-procedure were significantly lower in group 2 versus group 1 (U = -2.969, p = 0.003, and U = -2.674, p = 0.007, respectively). CONCLUSIONS: Our study showed a lower incidence rate of large bore arterial access complications as hematoma, a shorter procedure time, and a shorter hospital stay with percutaneous closure devices compared to surgical cutdown.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A comparative study between surgical cut down and percutaneous closure devices in management of large bore arterial access
Date Crossref
30/10/2023
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Infectious Aortic and Vascular ConditionsVascular Procedures and ComplicationsAortic Disease and Treatment Approaches

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.