A comparative study between surgical cut down and percutaneous closure devices in management of large bore arterial access
Rattachement africain : Égypte. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Compared to conventional open surgery, minimally invasive catheter-based procedures have less post procedural complications. Transcatheter aortic valve implantation (TAVI) and endovascular aneurysm repair (EVAR) require large bore arterial access. Optimal site management of large bore arterial access is pivotal to reduce the hospital-acquired complications associated with large bore arterial access. We wanted to compare surgical cutdown versus percutaneous closure devices in site management of large bore arterial access. METHODS: Participants planned for TAVI or EVAR with large bore arterial access more than 10 French were included, while participants with history of bypass surgery, malignancies, thrombophilia, or sepsis were excluded. A consecutive sample of 100 participants (mean age 74.66 ± 2.65 years, 61% males) was selected, underwent TAVI or EVAR with surgical cutdown (group 1) versus TAVI or EVAR with Proglide™ percutaneous closure device (group 2). RESULTS: The incidence rate of hematoma was significantly lower in group 2 versus group 1 (p = 0.014), the mean procedure time (minutes) and the median hospital stay (days) were significantly higher in group 1 versus group 2 (t(98) = - 2.631, p = 0.01, and U = 2.403, p = 0.018, respectively), and the c-reactive protein pre-procedure and the c-reactive protein post-procedure were significantly lower in group 2 versus group 1 (U = -2.969, p = 0.003, and U = -2.674, p = 0.007, respectively). CONCLUSIONS: Our study showed a lower incidence rate of large bore arterial access complications as hematoma, a shorter procedure time, and a shorter hospital stay with percutaneous closure devices compared to surgical cutdown.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A comparative study between surgical cut down and percutaneous closure devices in management of large bore arterial access
- Date Crossref
- 30/10/2023
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.