Assessing ICS responsiveness in severe asthma using BDP/formoterol NEXThaler™ dose-counting

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background: 65% of people with severe asthma and FeNO ≥45 ppb are non-adherent to inhaled corticosteroids (ICS). Digital monitoring that records both time-of-use and inhaler technique can identify non-adherence and ICS responsiveness but these devices are not readily available. As the dose counter on the NEXThaler™ only counts down when an inspiratory flow of 35 L/min is achieved, this may present an alternative to identifying ICS responsiveness. Aim: To use BDP/formoterol (200/6 mcg, 2 bd) NEXThaler® (BFN) dose-counting to assess ICS responsiveness in severe asthma. Methods: Severe asthmatics with a FeNO ≥45 ppb were trained to use BFN in place of their usual ICS/LABA. Patients re-attended 28 days later and the dose count was recorded. Day 0 and 28 FeNO, ACQ6 and blood eosinophils were recorded. A log10∆FeNO ≥0.24 defined FeNO suppressors among the study group, confirming ICS responsiveness. Results: All patients(n=25)completed day 28 follow up.12/25 (48%) suppressed their FeNO (median[IQR] pre 104[68-173], post 46[25-54] ppb, p<0.0001). A smaller reduction occurred in FeNO non suppressors (pre 121 [77-198], post 86[64-183] ppb, p=0.015). ACQ6 and blood eosinophil count fell in FeNO suppressors (ACQ mean±SEM pre 2.9[±0.3], post1.9 [±0.3] p=0.0012); Eos median[IQR] pre-0.43[0.32-0.9], post 0.15[0.11-0.33], p=0.016 [n=8]). Of 9 people with baseline ICS/LABA prescription refills of >75%, 6 were FeNO suppressors suggesting prior non-adherence. Conclusion: Nexthaler™ dose counting demonstrates that 50% of people in a severe asthma service with FeNO ≥45 ppb respond to ICS when used regularly. This approach may miss some people with non-intentional non-adherence due to inhaler technique errors.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Assessing ICS responsiveness in severe asthma using BDP/formoterol NEXThaler™ dose-counting
Date Crossref
09/09/2023
Éditeur
European Respiratory Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Inhalation and Respiratory Drug DeliveryAsthma and respiratory diseases

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.