Cont-ID: detection of sample cross-contamination in viral metagenomic data
Rattachement africain : be. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: High-throughput sequencing (HTS) technologies completed by the bioinformatic analysis of the generated data are becoming an important detection technique for virus diagnostics. They have the potential to replace or complement the current PCR-based methods thanks to their improved inclusivity and analytical sensitivity, as well as their overall good repeatability and reproducibility. Cross-contamination is a well-known phenomenon in molecular diagnostics and corresponds to the exchange of genetic material between samples. Cross-contamination management was a key drawback during the development of PCR-based detection and is now adequately monitored in routine diagnostics. HTS technologies are facing similar difficulties due to their very high analytical sensitivity. As a single viral read could be detected in millions of sequencing reads, it is mandatory to fix a detection threshold that will be informed by estimated cross-contamination. Cross-contamination monitoring should therefore be a priority when detecting viruses by HTS technologies. RESULTS: We present Cont-ID, a bioinformatic tool designed to check for cross-contamination by analysing the relative abundance of virus sequencing reads identified in sequence metagenomic datasets and their duplication between samples. It can be applied when the samples in a sequencing batch have been processed in parallel in the laboratory and with at least one specific external control called Alien control. Using 273 real datasets, including 68 virus species from different hosts (fruit tree, plant, human) and several library preparation protocols (Ribodepleted total RNA, small RNA and double-stranded RNA), we demonstrated that Cont-ID classifies with high accuracy (91%) viral species detection into (true) infection or (cross) contamination. This classification raises confidence in the detection and facilitates the downstream interpretation and confirmation of the results by prioritising the virus detections that should be confirmed. CONCLUSIONS: Cross-contamination between samples when detecting viruses using HTS (Illumina technology) can be monitored and highlighted by Cont-ID (provided an alien control is present). Cont-ID is based on a flexible methodology relying on the output of bioinformatics analyses of the sequencing reads and considering the contamination pattern specific to each batch of samples. The Cont-ID method is adaptable so that each laboratory can optimise it before its validation and routine use.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Cont-ID: detection of sample cross-contamination in viral metagenomic data
- Date Crossref
- 13/10/2023
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Liège Plant Pathology Laboratory pays non établi dans la noticeUniversité ou école supérieure
-
Gembloux Agro-Bio Tech pays non établi dans la noticeUniversité ou école supérieure
-
DNAVision (Belgium) pays non établi dans la noticeEntreprise
Plant Pathology Laboratory — University of Liège, Gembloux Agro-Bio Tech et DNAVision (Belgium).
Une affiliation ne permet pas de déduire la nationalité d’un auteur.