Aller au contenu principal
2023 article

Performance Evaluation of Prestressed Girders with 17.8-mm (0.7-in.) Strands

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

There has been a growing interest in using large-diameter strands to alleviate congestion by using fewer strands, reduce the total number of girders by increasing girder spacing, increase the span length, and allow shallower girders. While the 2020 AASHTO LRFD Bridge Design Specifications included 17.8-mm (0.7-in.) strands by reference to AASHTO M203, these larger-diameter strands were not used in bridge construction primarily because AASHTO LRFD was silent about the design aspects of members reinforced with 17.8-mm (0.7-in.) strands. The presented multifaceted, multiyear research involved an extensive parametric design case study, nonlinear finite-element analyses, material characterization, component tests, and full-scale girder experiments. This paper focuses on the full-scale girder tests, which were used to examine development length, detailing requirements, and flexural and shear behavior and strength. Experimentally determined development lengths were found to be shorter than those prescribed by the AASHTO LRFD Specification. Flexural and shear strength could be determined using established procedures. The current minimum required amount of confinement reinforcement was found to be sufficient to confine 17.8-mm (0.7-in.) strands. The extension of bottom flange confinement reinforcement was found to be inadequate for cases with partially debonded 17.8-mm (0.7-in.) strands, but extension of bottom flange confinement reinforcement to 1.5d beyond the end of the girder was adequate for cases with no debonded strands. The minimum bottom flange confinement reinforcement required by the AASHTO LRFD Specification must be extended to at least 1.5d beyond the termination of the longest debonded length of 17.8-mm (0.7-in.) strands.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Performance Evaluation of Prestressed Girders with 17.8-mm (0.7-in.) Strands
Date Crossref
01/12/2023
Éditeur
American Society of Civil Engineers (ASCE)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Structural Behavior of Reinforced ConcreteConcrete Corrosion and DurabilityStructural Load-Bearing Analysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.