Thromboembolic Events With the Woven Endobridge Device: Incidence, Predictive Factors, and Management

8Citations signalées — pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND AND OBJECTIVES: The Woven EndoBridge (WEB) device has been increasingly used to treat wide-neck aneurysms showing a safe and effective profile, but a relatively high number of thromboembolic events (TEEs) have been reported with such treatment. We aimed to evaluate the incidence and management of TEEs and possible predictive factors related to WEB embolization of ruptured and unruptured intracranial aneurysms. METHODS: A single-center database with consecutive aneurysms treated with a WEB device between July 2012 and May 2022 was reviewed for intraoperative and delayed TEEs. Univariate and multivariable analyses were used to determine factors associated with TEEs. RESULTS: A total of 266 independent aneurysms were treated with WEB devices in 245 patients (mean age 55.78 ± 11.64 years, 169 (63.5%) females, 80 (30%) ruptured). The overall rate of TEEs is 13% (35/266), including 8.7% intraoperative. Symptomatic TEEs with clinical sequelae at a 3-month follow-up are reported to be 2.6% (7/266) with no TEE-related mortality. Both the replacement of a WEB device during the procedure (adjusted odds ratio = 2.61, 95% CI 1.24-5.49; P = .01) and ruptured aneurysms (adjusted odds ratio = 2.74, 95% CI 1.31-5.7; P = .007) were independent predictors of TEEs. A case-by-case management of intraprocedural TEE is also presented; tirofiban was successfully used in most cases of this cohort. CONCLUSION: In this study, we demonstrated that ruptured aneurysms and WEB device replacement during the procedure were independent predictive factors for TEEs. As a result, making the correct choice of WEB is crucial for improving treatment outcomes. Moreover, with proper medical management of TEEs, minimal morbidity and no mortality could be achieved, which reinforces the safety of the technique.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Thromboembolic Events With the Woven Endobridge Device: Incidence, Predictive Factors, and Management
Date Crossref
20/09/2023
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Vascular Procedures and ComplicationsIntracranial Aneurysms: Treatment and ComplicationsAortic aneurysm repair treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.