Aller au contenu principal
Accès ouvert déclaré 2023 article

Robot-Assisted Renal Surgery with the New Hugo Ras System: Trocar Placement and Docking Settings

37Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The current literature relating to the novel HugoTM RAS System lacks consistent data concerning the bedside features of robot-assisted partial nephrectomy (RAPN). To describe the trocar placement and docking settings for RAPN with a three-arm configuration to streamline the procedure with HugoTM RAS, between October 2022 and April 2023, twenty-five consecutive off-clamp RAPNs for renal tumors with the HugoTM RAS System were performed. We conceived a trouble-free three-arm setting to ease and standardize RAPN trocar placement and docking settings with HugoTM RAS. Perioperative data were collected. Post-operative complications were reported according to the Clavien–Dindo classification. The eGFR was calculated according to the CKD–EPI formula. Continuous variables were presented as the median and IQR, while frequencies were reported as categorical variables. Off-clamp RAPNs were successfully performed in all cases without the need for conversion or additional port placement. The median age and BMI were 69 years (IQR, 60–73) and 27.3 kg/m2 (IQR, 25.7–28.1), respectively. The median tumor size and R.E.N.A.L. score were 32.5 mm (IQR, 26–43.7) and 6 (IQR, 5–7), respectively. Two patients were affected by cT2 renal tumors. The median docking and console time were 5 (IQR, 5–6) and 90 min (IQR, 68–135.75 min), respectively, with slightly progressive improvements in the docking time achieved. No intraoperative complications occurred alongside clashes between instruments or with the bed assistant. In experienced hands, this simplified three-instrument configuration of the HugoTM RAS System for off-clamp RAPN resulted in feasible and safe practice, providing patient-tailored trocar placement and docking with non-inferior peri-perioperative outcomes to other robotic platforms.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Robot-Assisted Renal Surgery with the New Hugo Ras System: Trocar Placement and Docking Settings
Date Crossref
13/09/2023
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Renal cell carcinoma treatmentRenal and Vascular PathologiesOrgan Donation and Transplantation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.