Aller au contenu principal
2023 article

Intraobserver and Interobserver Reliability of the Computed Tomography–Based Classifications Used in Posterior Malleolar Fractures: The Haraguchi and Bartoníček-Rammelt Classifications

3Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : tr, kh. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Three main computed tomography (CT)-based classification systems have been defined and used for posterior malleolar fractures. The intraobserver and interobserver reliability of two of these systems has never been investigated. The aim of this study was to investigate the intraobserver and interobserver reliability of the Haraguchi (HC) and Bartoníček-Rammelt (BRC) classifications. METHODS: Axial and sagittal CT sections and three-dimensional reconstruction images of 60 fractures were evaluated twice by six observers at a 6-week interval. Cohen κ values for intraobserver reliability and Fleiss κ values for interobserver reliability were calculated. RESULTS: The interobserver reliability of the HC was fair in both assessments (Fleiss κ: 0.263 and 0.249 for the first and second evaluations, respectively). The interobserver reliability of the BRC was moderate in both evaluations (Fleiss κ: 0.535 and 0.447, respectively). The intraobserver reliability values (Cohen κ) of the HC were determined to be between 0.532 and 0.927 for the six observers. These values indicated moderate agreement for one observer, substantial for four, and very good for one. Intraobserver reliability values for the BRC were determined to be between Cohen κ of 0.626 and 0.884. Based on these values, the BRC's intraobserver reliability indicated substantial agreement for two observers and very good for four observers. CONCLUSIONS: Intraobserver and interobserver reliability values of the BRC were higher than those of the HC.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Intraobserver and Interobserver Reliability of the Computed Tomography–Based Classifications Used in Posterior Malleolar Fractures: The Haraguchi and Bartoníček-Rammelt Classifications
Date Crossref
01/07/2023
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Foot and Ankle SurgeryCorneal surgery and disordersFacial Trauma and Fracture Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.