Aller au contenu principal
Accès ouvert déclaré 2023 article

BIRADS 4 – Is it possible to downgrade lesions that do not enhance on recombinant contrast-enhanced mammography images?

10Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : pl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: Analysis of the morphology of lesions classified into the BI-RADS 4 category and assessment of the possibility of downgrade the BI-RADS category in those that did not show enhancement on recombinant contrast-enhanced mammography (CEM) images. METHOD: The retrospective, single-center study included 528 patients who underwent a core needle biopsy performed from January 2017 to November 2022 due to a breast lesion classified as BI-RADS 4 on CEM. Patients' electronic records and imaging examinations were reviewed. Individual lesions were classified into the morphological categories of mass, non-mass, and microcalcifications. Sensitivity, specificity, positive as well as negative predictive values were calculated for the whole group and individual morphological categories. The influence of the lesions' diameter on the results was analyzed. RESULTS: CEM NPV for the whole group was 93.9% (±95% CI: 90.0-96.4), for mass lesions 100% (±95% CI: 94.5-100), for non-mass lesions 97.8% (±95% CI: 87.0-99.9) and 87.9% (±95% CI: 80.3-93.0) for microcalcifications. Given that 230 out of 383 benign lesions were not contrast-enhancing, 60.1% of unnecessary CNBs would have been correctly avoided. CEM sensitivity for lesions < 20 mm was lower than for lesions ≥ 20 mm and was respectively 86.6% (±95% CI: 76.8-92.8) vs 94.6% (±95% CI: 86.0-98.2), respectively. CONCLUSION: CEM is characterized by high sensitivity in the detection of malignant lesions in the case of lesions with mass and non-mass morphology. The high NPV for recombinant images suggests that in the case of these lesions, the lack of enhancement supports the benign nature of the lesion and may lead to a downgrade of the BI-RADS category.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
BIRADS 4 – Is it possible to downgrade lesions that do not enhance on recombinant contrast-enhanced mammography images?
Date Crossref
01/10/2023
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Digital Radiography and Breast ImagingBreast Lesions and CarcinomasGlobal Cancer Incidence and Screening

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.