Optimized drug‐coated balloon angioplasty of the superficial femoral and proximal popliteal arteries using the Tack Endovascular System: Tack Optimized Balloon Angioplasty (TOBA) III 24‐month results in standard and long lesions

3Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : at, de, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: The Tack Endovascular System is a minimal-metal dissection repair device that is purpose-built to treat post-percutaneous angioplasty (PTA) arterial dissections in patients with peripheral arterial disease (PAD). The Tack Optimized Balloon Angioplasty (TOBA) III trial evaluated the safety and effectiveness of the Tack Endovascular System in patients with superficial femoral artery (SFA) and/or proximal popliteal artery (PPA) dissection after PTA with a drug-coated balloon (DCB). The objective of this study is to report the results in the standard- (SL) and long-lesion (LL) cohorts through 24 months. DESIGN: The TOBA III study was a prospective, multicenter, single-arm study including patients suffering from Rutherford category 2-4 PAD. Outcomes were assessed according to pre-specified lesion length in SL ( ≥ 20 mm and ≤150 mm) and LL ( > 150 mm and ≤250 mm) cohorts. Follow-up was through 24 months. RESULTS: TOBA III enrolled 201 patients, 169 patients in the SL cohort and 32 in the LL cohort. At 24 months, the Kaplan-Meier estimates of freedom from major adverse events were 91.7% and 82.6% for the SL cohort and LL cohort, respectively. Kaplan-Meier estimates of freedom from clinically driven-target lesion revascularization (CD-TLR) were 92.3% in the SL cohort and 82.6% in the LL cohort. At 24 months, 78.8% of SL patients and 69.2% of LL patients experienced an improvement of >2 Rutherford categories (both cohorts p < 0.001). The baseline ankle-brachial index improved from 0.68 ± 0.18 to 0.93 ± 0.16 in the SL (p < 0.001) and from 0.62 ± 0.23 to 0.87 ± 0.15 in the LL cohort (p < 0.001) at 24 months. CONCLUSION: The 24-month results of the TOBA III trial support the safety and effectiveness of the Tack Endovascular System in patients who required post-PTA dissection repair in the SFA and PPA following DCB angioplasty for claudication and rest pain. In both the SL and LL cohorts, Tack placement was associated with sustained freedom from CD-TLR through 24 months as well as sustained improvements in Rutherford categories, ankle-brachial index, and quality of life.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Optimized drug‐coated balloon angioplasty of the superficial femoral and proximal popliteal arteries using the Tack Endovascular System: Tack Optimized Balloon Angioplasty (TOBA) III 24‐month results in standard and long lesions
Date Crossref
10/08/2023
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Peripheral Artery Disease ManagementVascular Procedures and ComplicationsCerebrovascular and Carotid Artery Diseases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.