Aller au contenu principal
Accès ouvert déclaré 2023 article

Is it time for a retinoic acid-eluting stent or retinoic acid-coated balloon? Insights from experimental studies of systemic and local delivery of retinoids

3Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Although the incidence of restenosis and stent thrombosis has substantially declined during the last decades, they still constitute the two major causes of stent failure. These complications are partially attributed to the currently used cytostatic drugs, which can cause local inflammation, delay or prevent re-endothelialization and essentially cause arterial cell toxicity. Retinoic acid (RA), a vitamin A (retinol) derivative, is a naturally occurring substance used for the treatment of cell proliferation disorders. The agent has pleiotropic effects on vascular smooth muscle cells and macrophages: it influences the proliferation, migration, and transition of smooth muscle cells to other cell types and modulates macrophage activation. These observations are supported by accumulated evidence from in vitro and in vivo experiments. In addition, systemic and topical administration of RA can decrease the development of atherosclerotic plaques and reduce or inhibit restenosis after vascular injury (caused by embolectomy, balloon catheters, or ligation of arteries) in various experimental models. Recently, an RA-drug eluting stent (DES) has been tested in an animal model. In this review, we explore the effects of RA in atherosclerosis and the potential of the local delivery of RA through an RA-DES or RA-coated balloon for targeted therapeutic percutaneous vascular interventions. Despite promising published results, further experimental study is warranted to examine the safety and efficacy of RA-eluting devices in vascular artery disease.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Is it time for a retinoic acid-eluting stent or retinoic acid-coated balloon? Insights from experimental studies of systemic and local delivery of retinoids
Date Crossref
01/03/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Retinoids in leukemia and cellular processesAngiogenesis and VEGF in CancerAntioxidant Activity and Oxidative Stress

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.