Semisupervised Learning with Report-guided Pseudo Labels for Deep Learning–based Prostate Cancer Detection Using Biparametric MRI

56Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose To evaluate a novel method of semisupervised learning (SSL) guided by automated sparse information from diagnostic reports to leverage additional data for deep learning–based malignancy detection in patients with clinically significant prostate cancer. Materials and Methods This retrospective study included 7756 prostate MRI examinations (6380 patients) performed between January 2014 and December 2020 for model development. An SSL method, report-guided SSL (RG-SSL), was developed for detection of clinically significant prostate cancer using biparametric MRI. RG-SSL, supervised learning (SL), and state-of-the-art SSL methods were trained using 100, 300, 1000, or 3050 manually annotated examinations. Performance on detection of clinically significant prostate cancer by RG-SSL, SL, and SSL was compared on 300 unseen examinations from an external center with a histopathologically confirmed reference standard. Performance was evaluated using receiver operating characteristic (ROC) and free-response ROC analysis. P values for performance differences were generated with a permutation test. Results At 100 manually annotated examinations, mean examination-based diagnostic area under the ROC curve (AUC) values for RG-SSL, SL, and the best SSL were 0.86 ± 0.01 (SD), 0.78 ± 0.03, and 0.81 ± 0.02, respectively. Lesion-based detection partial AUCs were 0.62 ± 0.02, 0.44 ± 0.04, and 0.48 ± 0.09, respectively. Examination-based performance of SL with 3050 examinations was matched by RG-SSL with 169 manually annotated examinations, thus requiring 14 times fewer annotations. Lesion-based performance was matched with 431 manually annotated examinations, requiring six times fewer annotations. Conclusion RG-SSL outperformed SSL in clinically significant prostate cancer detection and achieved performance similar to SL even at very low annotation budgets. Keywords: Annotation Efficiency, Computer-aided Detection and Diagnosis, MRI, Prostate Cancer, Semisupervised Deep Learning Supplemental material is available for this article. Published under a CC BY 4.0 license.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Semisupervised Learning with Report-guided Pseudo Labels for Deep Learning–based Prostate Cancer Detection Using Biparametric MRI
Date Crossref
01/09/2023
Éditeur
Radiological Society of North America (RSNA)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Prostate Cancer Diagnosis and TreatmentAI in cancer detectionAdvanced Radiotherapy Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.