Normothermic ex vivo lung perfusion using a developed solution followed by orthotopic left lung transplantation (experimental study)

8Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : ru, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The continued unavailability of adequate organs for transplantation to meet the existing demand has resulted in a major challenge in transplantology. This is especially felt in lung transplantation (LTx). LTx is the only effective method of treatment for patients with end-stage lung diseases. Normothermic ex vivo lung perfusion (EVLP) has been proposed to increase the number of donor organs suitable for transplant – EVLP has proven itself in a number of clinical trials. The ability to restore suboptimal donor lungs, previously considered unsuitable for transplantation, can improve organ functionality, and thus increase the number of lung transplants. However, widespread implementation of ex vivo perfusion is associated with high financial costs for consumables and perfusate. Objective: to test the developed solution on an ex vivo lung perfusion model, followed by orthotopic LT under experimental conditions. Materials and methods. The experiment included lung explantation stages, static hypothermic storage, EVLP and orthotopic left LTx. Perfusion was performed in a closed perfusion system. We used our own made human albumin-based perfusion solution as perfusate. Perfusion lasted for 2 hours, and evaluation was carried out every 30 minutes. In all cases, static hypothermic storage after perfusion lasted for 4 hours. The orthotopic single-lung transplantation procedure was performed using assisted circulation, supplemented by membrane oxygenation. Postoperative follow-up was 2 hours, after which the experimental animal was euthanized. Results. Respiratory index before lung explantation was 310 ± 40 mmHg. The PaO2/FiO2 ratio had positive growth dynamics throughout the entire EVLP procedure. Oxygenation index was 437 ± 25 mm Hg after 120 minutes of perfusion. Throughout the entire EVLP procedure, there was a steady decrease in pulmonary vascular resistance (PVR). Initial PVR was 300 ± 100 dyn×s/cm5; throughout the EVLP, PVR tended to fall, reaching 38,5 ± 12 dyn×s/cm5 at the end of perfusion. Conclusion. A safe and effective EVLP using our perfusate is possible. The developed orthotopic left lung transplantation protocol under circulatory support conditions, supplemented by membrane oxygenation, showed it is efficient and reliable.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Normothermic <i>ex vivo</i> lung perfusion using a developed solution followed by orthotopic left lung transplantation (experimental study)
Date Crossref
16/07/2023
Éditeur
V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Transplantation: Methods and OutcomesOrgan Transplantation Techniques and OutcomesMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.