Are Confirmatory Assays Reliable for HIV-1/HIV-2 Infection Differentiation? A Multicenter Study
Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Immunoblots remain the gold standard for HIV-1/HIV-2 infection confirmation. However, their ability to differentiate HIV-1 from HIV-2 infection on an antigenically diversified HIV-1 and HIV-2 panel remain uncommon. We performed a multicenter study on 116 serum samples accounting for most of the diversity of HIV-1 (9 different subtypes in group M, 17 circulating recombinant forms (CRFs), and 3 group O) and HIV-2 (groups A and B), evaluating seven confirmatory assays (six commercially available assays and one in-house assay) with genotyping as the reference. The assays were INNO-LIA HIV I/II score, HIV-2 blot 1.2, HIV blot 2.2, New Lav blot I and II, Geenius, and an in-house serotyping enzyme-linked immunosorbent assay (ELISA). Among the HIV-1 samples, INNO-LIA, HIV blot 2.2, New Lav blot I, Geenius, and serotyping had comparable high sensitivities, from 98% to 100%, whereas HIV-2 blot 1.2 and New Lav blot II had high rates of "undetermined" results (85% and 95%, respectively). HIV-2 blot 1.2 and New Lav blot II misclassified 7% and 5% of HIV-1 samples as HIV-2, respectively, and HIV-2 blot 1.2 had an 8% false-negative rate. Among the HIV-2 samples, INNO-LIA, New Lav blot II, HIV-2 blot 1.2, and serotyping had high sensitivities, from 96% to 100%. HIV blot 2.2 misclassified 17% of HIV-2 samples as HIV-1/HIV-2 dual infections. New Lav blot I misclassified 19% of HIV-2 samples as HIV-1 with a high (81%) undetermined rate, and Geenius misclassified 2% as HIV-1 and 7% as untypeable HIV positive. For HIV-1/HIV-2 dual infection, the results were less sensitive, with at most 87.5% for INNO-LIA and Geenius and 75% for HIV blot 2.2 and serotyping. Overall, confirmatory assays remain useful for most cases, with the exception of HIV-1/HIV-2 dual-infection suspicion.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Are Confirmatory Assays Reliable for HIV-1/HIV-2 Infection Differentiation? A Multicenter Study
- Date Crossref
- 17/07/2023
- Éditeur
- American Society for Microbiology
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.